• <tr id='SUkdx9'><strong id='SUkdx9'></strong><small id='SUkdx9'></small><button id='SUkdx9'></button><li id='SUkdx9'><noscript id='SUkdx9'><big id='SUkdx9'></big><dt id='SUkdx9'></dt></noscript></li></tr><ol id='SUkdx9'><option id='SUkdx9'><table id='SUkdx9'><blockquote id='SUkdx9'><tbody id='SUkdx9'></tbody></blockquote></table></option></ol><u id='SUkdx9'></u><kbd id='SUkdx9'><kbd id='SUkdx9'></kbd></kbd>

    <code id='SUkdx9'><strong id='SUkdx9'></strong></code>

    <fieldset id='SUkdx9'></fieldset>
          <span id='SUkdx9'></span>

              <ins id='SUkdx9'></ins>
              <acronym id='SUkdx9'><em id='SUkdx9'></em><td id='SUkdx9'><div id='SUkdx9'></div></td></acronym><address id='SUkdx9'><big id='SUkdx9'><big id='SUkdx9'></big><legend id='SUkdx9'></legend></big></address>

              <i id='SUkdx9'><div id='SUkdx9'><ins id='SUkdx9'></ins></div></i>
              <i id='SUkdx9'></i>
            1. <dl id='SUkdx9'></dl>
              1. <blockquote id='SUkdx9'><q id='SUkdx9'><noscript id='SUkdx9'></noscript><dt id='SUkdx9'></dt></q></blockquote><noframes id='SUkdx9'><i id='SUkdx9'></i>

                Instrument Center

                LineGene Mini

                Line Gene Mini is a portable fluorescence quantitative PCR instrument developed by the Bioer company to deal with diversified and complex environment. This product adopts the small capacity design of 16 single-tube , and can be used for battery power supply.At the same time, this new generation of PCR is used to create a new generation of fluorescence quantitative PCR with a customized version of Peltier module, new optical path design and top scanning.
                Application environment:  1,field operation, such as field, forest farm, farm and water source.2, disaster area or the field hospital, to make rapid and accurate clinical diagnosis of the disaster. Of course, it is also convenient for the handling and use of the lab.

                • parameter
                • download

                 Model

                 FQD-16A

                 Sample Capacity

                 16 x 0.2ml tubes (flat and transparent cap) 

                 2 x 8-tube strips (flat and transparent cap}

                 Reaction Volume

                 10 -100ul

                 Temperature Control Mode

                 Tube mode

                 Temperature Control Method

                 Peltier

                 Temperature Range

                 0- 100℃

                 Maximum Heating/Coaling Rate

                 5℃/s

                 Average Heating/cooling Rate

                 3.5℃/s

                 Temperature Resolution

                 0.1℃

                 Temperature Uniformity

                 士0.15℃

                 Temperature Accuracy

                 士0.1℃

                 Hot-Lid Temperature Range

                 85-110℃

                 Excitation Wavelength Range

                 400 to 700nm

                 Detection Wavelength Range

                 450 to 750nm

                 Sensitivity

                 1 copy

                 Dynamic Range

                 1-1010 Copies

                 Factory Calibrated Dyes

                 BYQ 6618E

                 BYQ 6622E

                 BYQ 6623E

                  F1: FAM, 

                SYBR Green1
                  F3: ROX

                  F1 ; FAM, SYBR Green 1
                  F2: VIC, HEX,  TET,  JOE, TAMRA CY3,  NED

                  F1 : FAM, SYBR Green1
                  F2: VIC, HEX, TET, JOE, TAMRA, CY3, NED
                  F3; ROX
                  F4:CY5

                 Dimension

                 W280xD220xH240

                 Net Weight

                 6.5 kg

                 Adapter Input Voltage

                 100 - 240V

                 Adapter Input Frequency

                 50 - 60Hz

                 Power

                 DC 24V 180 w. power adaptor needed

                 Connection Options

                 USB port

                 Safety Protection and Alarm

                 Block, hot lid and heat sink temperature sensors shart circuit, open circuit alarm and pratection; Hot lid over temperature alarm and protection

                 Environment Temperature Range

                 5-35℃

                 Safety Certification 

                 IVD, CE MET, RoHS 2.0

                 Warm-up Time

                 No

                Privacy clause

                Respect the user's privacy is a basic policy of Hangzhou Bioer user service. Hangzhou Boier will not disclosure user information to third parties or disclose their registration and preservation of non disclosure in Hangzhou Bioer platform, except in the following situations: (1)User's improper behavior caused leakage of privacy information ; (2)Caused by network, hacker attack, computer virus, government regulation, the reasons of the leakage, lost, stolen or tampered with other relevant legal requirements; (3)Law-enforcement agency asked Hangzhou Bioer to provide privacy information of the user; (4)Emergency situation when public life and property security is under threate.

                Exemption clause

                Hangzhou Bioer technology does not guarantee the accuracy, integrity and reliability of any content on this website and any content that may use these results. Hangzhou Bioer technology and related people can not guarantee that you can enter, browse and use this website at any time; Hangzhou Bioer technology on this website and its contents can not use and do not take any responsibility. The site links to other websites that Hangzhou itself is not recognized or undertake other Bioer technology content or the use of responsibility. Hangzhou Bioer technology and related people to enter, browse and use of the site, from the website to download any content or by any link to this site to other sites caused by viruses or other destructive programs on your computer system and any other software and hardware, IT system or property damage or loss does not bear any responsibility. Hangzhou Bioer technology and the relevant people do not bear any responsibility caused by the third party using illegal means to obtain the password, data and content into the site of any direct and indirect damage or loss . The final interpretation belong to Hangzhou Bioer Technology Co. Ltd.

                Hangzhou Bioer reserves the right to correct, modify and update this statement at any time.

                Copyright

                This website from Hangzhou Bioer Technology Co. Ltd. (hereinafter referred to as "Hangzhou Bioer") the creation of any content of this website (including but not limited to text, data, graphics, images, voice or video) are copyright or related rights belong to Hangzhou Bioer. Hangzhou Bioer or related rights without prior written permission, you shall not in any way without permission to copy, reconstruction, spread, publishing, reprint, repost or display the contents of this website. Any unauthorized use of this site may violate the "Copyright Law of People's Republic of China " and other relevant laws and regulations and international conventions, Hangzhou Bioer fully pursue appropriate legal responsibility right.

                Contact Us

                Address: 1192 Bin An Rd, Hi-tech (Binjiang)District,Hangzhou,310053,P. R. China

                Tel:0571-87774567